Date: Sun, 25 Mar 2012 09:20:42 +0900
--------------------------------------------------
2012/07/19
Coming Soon ...
"The previous Thermal Guidelines (Thermal & Liquid Cooling) have been
remove due to the anticipated release of the 3rd Edition of
the Thermal Guidelines which will be published soon. Please check back
to the site for the latest updates."
July 6, 2012, ASHRAE Technical Committee 9.9
http://tc99.ashraetcs.org/
--------------------------------------------------
2011年 9月に、ASHRAE (American Society of Heating, Refrigerating and
Air-Conditioning Engineers) から、液冷に関する White Paperが公開されて
ました:
"ASHRAE Introduces New Liquid Cooled Datacom Environmental Classes"
Sep 27, 2011
http://www.ashrae.org/news/2011/ashrae-introduces-new-liquid-cooled-datacom-environmental-classes
""2011 Thermal Guidelines for Liquid Cooled Data Processing Environments"
creates data center classes for liquid cooling that can enable fulltime
economizers for a number of applications in many climates, according
to according to Don Beaty, chair of the Publications Subcommittee of
ASHRAE's Technical Committee (TC) 9.9, Mission Critical Facilities,
Technology Spaces and Electronic Equipment."
.....
"This whitepaper follows an earlier whitepaper released in May 2011,
"2011 Thermal Guidelines for Data Processing Environments - Expanded
Data Center Classes and Usage Guidance," which addresses air cooling
in data centers and created new data center environmental classes
which expanded the opportunity for chiller-less data centers
(fulltime economizers)."
"2011 ASHRAE Thermal Guidelines for Liquid Cooled Data Processing Environments"
ASHRAE TC 9.9, 2011
http://tc99.ashraetcs.org/documents/ASHRAE%202011%20Liquid%20Cooling%20Whitepaper.pdf
Introduction
.....
"Developing these new classes among the commercial IT manufacturers
in consultation with the Energy Efficient High Performance Computing
(EE HPC) Working Group (WG) should produce better results since
the sharing of some critical data among them has proven in the past
to achieve broader environmental specifications than what otherwise
would have been achieved."
APPENDIX B. Energy Efficient High Performance Computing Working Group
"The Energy Efficient High Performance Computing (EE HPC) Working Group
(WG) is an ad-hoc group, with logistics and organizational support
from the DOE. The WG is open to all HPC practitioners from
the US National Labs and others involved or interested in HPC.
The WG efforts were focused on establishing the ideal water supply
temperatures for the National labs. The activity begins with
a survey of National Lab locations and respective dry bulb (DB) and
wet bulb (WB) temperatures extremes."
ASHRAE TC 9.9 Documents
http://tc99.ashraetcs.org/documents.html
ASHRAE TC 9.9
http://tc99.ashraetcs.org/
直前のメールと繰り返しになりますが
[san-tech][03104] ASHRAE Whitepaper - 2011 Thermal Guidelines公開
Date: Sun, 22 May 2011 19:44:36 +0900>
> "2011 Thermal Guidelines for Data Processing Environments Expanded
> Data Center Classes and Usage Guidance"
> Whitepaper prepared by ASHRAE Technical Committee (TC) 9.9
> http://tc99.ashraetcs.org/documents/ASHRAE%20Whitepaper%20-%202011%20Thermal%20Guidelines%20for%20Data%20Processing%20Environments.pdf
>
> "Thermal Guidelines Whitepaper - Expands allowable temperature
> ranges and provides new environmental metrics to guide the data
> center industry."
==================================================
[san-tech][02992] ASHRAE:サーバ稼働奨励温度範囲を拡大へ
[san-tech][03377] デル、最高45℃での使用も保証で外気冷却を支援、2011/08/24、@IT
[san-tech][03488] Slide: Green Grid Forum 2012 (March 6-7, 2012) & Free Cooling Map Update
0 件のコメント: